Pompa pressure 200bar W200-15

Pompa yang digunakan untuk hydrotest, membersihkan mobil, container, jalan, dan lain - lain sesuai dengan kebutuhannya.

Type W200 - 15 EPT

Spesifikasi :
Pressure : 200 bar
Flow rate : 15 LPM
Power : 5.5kw
Switch : On / Off with safety RCCB
Accesories : hose inlet dan outlet, vega gun, nozzle
Untuk informasi lebih lanjut bisa menghubungi : Hafes - 0812 9070861 
website : www.solusijaya.com
Email : hafezbahanan@solusijaya.com

Kamis, 02 April 2020

pompa hydrotest 200bar

Unit Type W200-18DPT
Spesifikasi : 
* pressure max 200bar
* flow rate 18lpm
* power 10hp c/w engine

Aplication for :
* Hydrotest
* Pipe cleaning.
* Car wash
* Heavy duty cleaning.
* Misting.

For best price call : 0812-9070861
Email : hafezbahanan@solusijaya.com


Kamis, 24 Oktober 2019

Hydrotest

Tips Aman Melakukan Hydrostatic Test

Pastikan, sebelum melakukan hydrostatic test, anda sudah mempelajari prosedurnya dengan baik. Dan bagaimana cara melakukannya dengan aman.
bahaya hydrotestNah, tips berikut ini dapat membantu anda bagaimana melakukan hydrostatic test secara aman, tanpa membahayakan diri anda dan orang lain, serta fasilitas di sekitarnya.
  • Hanya mereka yang terlatih dan memiliki wewenang yang dapat melakukan hydrostatic test.
  • Yakinkan kondisi pengujian dengan tekanan desain dari alat yang akan diuji. Pastikan tekanan yang digunakan sesuai dengan standar yang ada. Jangan sampai tekanan uji lebih tinggi dari desain alat.
  • Seluruh perpipaan, hose dan semua alat yang terlibat dalam hydrostatic test mempunyai kekuatan yang lebih tinggi daripada tekanan pengujian.
  • Pastikan pula seluruh perpipaan, valve dan fitting yang diuji sudah diketahui spesifikasinya dengan yakin. Periksa kembali dokumen terkait.
  • Jangan pernah menggunakan material yang rentan akan kerusakan, getas apalagi yang sudah retak karena karatan.
  • Semua material yang akan digunakan ulang pada saat pengujian dengan hydrotest harus diperiksa kondisinya terlebih dahulu. Jangan hanya asal menggunakan. Sangat berbahaya.
  • Support pipa dan peralatan yang terkena uji ini harus memiliki kekuatan yang mencukupi atau lebih tinggi dari tekanan uji.
  • Pressure-relief device seperti safety valve harus tersedia, untuk mencegah terjadinya over pressure.
  • Pastikan tidak ada udara yang terjebak di dalam pipa atau alat yang akan diuji karena sangat berbahaya.
  • Hanya mereka yang berwenang saja yang diperkenankan berada di dalam area pelaksanaan hydrostatic test.
  • Area tempat pelaksanaan hydrostatic test harus diamankan dengan safety line dan jika perlu dengan safety barrier, untuk mecegah orang yang tidak berwenang memasuki area dan mengisolasi potensi bahaya yang muncul.
  • Akan lebih baik lagi, jika di sekitar area tersebut dilengkapi dengan tanda bahaya yang menunjukkan bahwa hydrotest sedang dilaksanakan.
  • Jangan lupa gunakan selalu APD atau alat pelindung diri yang sesuai selama proses pengujian berlangsung.
  • Gunakan hanya pressure gauge yang terkalibrasi. Pastikan range pengukurannya antara 1.5 sampai 2 kali tekanan pengujian.
  • Sebelum memulai pelaksanaan hydrotest pastikan safety permit atau ijin kerja aman sudah didapatkan.
  • Jauh-jauh hari sebelum pelaksanaan dimulai, komunikasikan dengan pihak-pihak terkait.
  • Hentikan test saat itu juga apabila ditemukan kondisi tidak aman atau potensi bahaya terdeteksi.
  • Jangan pernah berdiri tepat di depat pressure gauge selama tes berlangsung. Sangat berbahaya.
  • Pastikan pencahayaan atau penerangan yang cukup selama tes berlangsung.
  • Apabila hydrotest sudah selesai, maka yang pertama kali dilakukan adalah mengeluarkan tekanan dari dalam pipa atau alat secara perlahan. Setelah itu, baru air dikeluarkan.

Selasa, 01 Maret 2016

Misting Pump

MISTING Strong of our 30-year experience in high pressure cleaning we are proud to introduce our new range of misting pumps and accessories for cooling systems, humidification, dust suppression, odour neutralization in residential, commercial, industrial and agriculture applications. Our pumps meet the most rigorous needs of quality, compactness, noiselessness and low cost required by the market.

Rabu, 24 Februari 2016

Testing Procedures

Testing procedures

Hydrostatic tests are conducted under the constraints of either the industry's or the customer's specifications, or may be required by law. The vessel is filled with a nearly incompressible liquid - usually water or oil - pressurised to test pressure, and examined for leaks or permanent changes in shape. Red or fluorescent dyes may be added to the water to make leaks easier to see. The test pressure is always considerably higher than the operating pressure to give a factor of safety. This factor of safety is typically 166.66%, 143% or 150% of the designed working pressure, depending on the regulations that apply. For example, if a cylinder was rated to DOT-2015 PSI (approximately 139 bar), it would be tested at around 3360 PSI (approximately 232 bar). Water is commonly used because it is cheap and easily available, and is usually harmless to the system to be tested. Hydraulic fluids and oils may be specified where contamination with water could cause problems. These fluids are nearly incompressible, therefore requiring relatively little work to develop a high pressure, and is therefore also only able to release a small amount of energy in case of a failure - only a small volume will escape under high pressure if the container fails. If high pressure gas were used, then the gas would expand to V=(nRT)/p with its compressed volume resulting in an explosion, with the attendant risk of damage or injury. This is the risk which the testing is intended to mitigate.


Water jacket test
Small pressure vessels are normally tested using a water jacket test. The vessel is visually examined for defects and then placed in a container filled with water, and in which the change in volume of the vessel can be measured, usually by monitoring the water level in a calibrated tube. The vessel is then pressurized for a specified period, usually 30 or more seconds, and if specified, the expansion will be measured by reading off the amount of liquid that has been forced into the measuring tube by the volume increase of the pressurized vessel. The vessel is then depressurized, and the permanent volume increase due to plastic deformation while under pressure is measured by comparing the final volume in the measuring tube with the volume before pressurization. A leak will give a similar result to permanent set, but will be detectable by holding the volume in the pressurized vessel by closing the inlet valve for a period before depressurizing, as the pressure will drop steadily during this period if there is a leak. In most cases a permanent set that exceeds the specified maximum will indicate failure. A leak may also be a failure criterion, but it may be that the leak is due to poor sealing of the test equipment. If the vessel fails, it will normally go through a condemning process marking the cylinder as unsafe.
The information needed to specify the test is stamped onto the cylinder. This includes the design standard, serial number, manufacturer, and manufacture date. After testing, the vessel or its nameplate will usually be stamp marked with the date of the successful test, and the test facility's identification mark.
A simpler test, that is also considered a hydrostatic test but can be performed by anyone who has a garden hose, is to pressurize the vessel by filling it with water and to physically examine the outside for leaks. This type of test is suitable for containers such as boat fuel tanks, which are not pressure vessels but must work under the hydrostatic pressure of the contents. A hydrostatic test head is usually specified as a height above the tank top. The tank is pressurized by filling water to the specified height through a temporary standpipe if necessary. It may be necessary to seal vents and other outlets during the test.

Rabu, 17 Februari 2016

hydrotest

PT.SOLUSI JAYA. Our company is a distributor Hawk Pumps, Pumps and Pump Pratissoli we imported directly from Italy. pressure of 100 bar to 1500 bar.   
TRADE PUMP HAWK, PRATISSOLLI   
HIGH PRESSURE CLEANER PUMP.HIGH PRESSURE, HIGH PRESSURE WATER BLASTER   
Pressure - 110 bar - 1500 bar / 1450 psi - 21, 750 psi   
Flow rate - 12 L / M - 200 L / M     
1. Electric driven high pressure pump.     
2. The high pressure pump driven machine     
3. Hot and cold high pressure pump.     
4. Spare parts, accessories HAWK pump, PRATISSOLI.     
5. Hydrotest Pump 1450 PSI - 15500 PSI.     
To: Automotive, Industrial, Heavy equipment, work location, breathe, Wet Sandblasting, Tube Cleaning, Hydro test, Heat ex Changer, etc

For detail product contact us at PT. Solusi Jaya - jl. Jend pol rs soekanto no.34 Pondok kopi - duren sawit


Phone. 021 8626306 , 021-86612083
Hp: 08119132005 , 08129070861

w100-8 EMS

Pompa hydrotest dengan spesifikasi : ▶pressure max : 100 bar ▶flow rate : 8 lpm ▶power : 1,5 kw ▶gauge : pressure gauge wika 400 bar Untuk info lebih lanjut: www.solusijaya.com